THE SINGLE BEST STRATEGY TO USE FOR DP50RB

The Single Best Strategy To Use For Dp50rb

The Single Best Strategy To Use For Dp50rb

Blog Article

The person is not really allowed to open up the addresses and panel in the process, neither Be aware: unit disassemble is permitted. To make sure the process overall performance and security, only Mindray engineers or engineers authorized by Mindray can execute maintenance.

The DP-fifty Specialist is definitely an impressive, higher-performance Ultrasound Program engineered to assist you to get the insights you will need. The Program’s effective engine and superior-speed processing provide excellent image high-quality and a whole info administration Option.

Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi element mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.

Permits utilization of various scanned angles to type one graphic, resulting in enhanced distinction resolution and enhanced visualization

Webpage 145 Thoroughly clean user interface Instruments: dry comfortable fabric, delicate soapy drinking water  Technique:  Use dry gentle fabric to wash the surface in the technique. When the program is dirty, moisten the tender cloth with mild soapy drinking water and wipe off any stains. Use dry gentle cloth to eliminate any moisture and allow all really hard surfaces to totally air-dry. Web site 146: Clean up The Peripherals

Tend not to use any cables other than the cables presented with the system by Mindray. 3. Make use of the cable presented with this system to connect the printer. Other cables may result in electrical shock. Page 15: Mechanical Security

Overall performance Check five.five.one Exam Method Resolution Detection depth Geometric Posture Accuracy Blackout spot exam Document the Examination images 5.five.two Test Material The impression made use of Here's just for reference, stay with the graphic impact in the real Take note: condition. Prerequisites: Display screen: set the contrast and brightness with the clinical software price (or perhaps the default status) Operation setting: darkish place, simulating the scientific software ecosystem. Web page seventy six In ailment that the transverse resolution screening targets are horizontally shown, file the nominal length of two targets which might be Plainly identified. Repeat the operation higher than for that transverse resolution testing targets at other depths. As demonstrated in determine under. Axial resolution ... Webpage seventy seven When utilizing the convex probe, preserve the transverse resolution tests targets to NOTE: be displayed near the midline. When utilizing a linear probe with steer function, tend not to activate the steer purpose when execute the transverse resolution take a look at. Zoom within the area exactly where the targets Positioned if necessary. The diameter of the goal place at a specific depth is equal to the transverse resolution for the depth. Web site 78 5.

Find superior diagnostic facts by way of extended view of your anatomical composition on all linear probes

Utmost four occasions tasking for a single transmitted beam, leading to exceptional time resolution and better body level.

Soon after changing the CPU module, critical Dp50rb file should be produced Once more according to the new MAC deal with and composed into HDD with the equipment. Or else, the configuration operate in the merchandise might be missing. Immediately after taking away the CPU module, Take away panhead screws with washers (12 M3X6) preset on the most crucial unit box, you may take from the board. Webpage 118 Determine 8-29 Disassemble the Control Panel Assembly (one) Hold the upper fringe of user interface assembly, and open up up the control panel. Figure eight-thirty Disassemble the Control Panel Assembly (2) After eradicating a single countersunk head self-tapping screw PT3X10 preset around the control panel and choose out the plug in the keyboard and the most crucial unit connecting cables, you could possibly get rid of the control panel assembly.

Once you prevent the scanning as well as the impression seize, you should electricity off the technique and disconnect the process with the AC electric power source, then pull out AC power cables. Web page 109: Battery Connecting Board

This handbook may referring to info guarded by copyright or patents and isn't going to convey any license under the patent rights or copyright of Mindray, or of Some others. Site nine: Statement

probe. The picture abnormality could possibly be a result of Switch the probe, or maybe the swivel of your 4D probe or perhaps the 4D generate replace the 4D travel board board.

Notice: To the keep an eye on, the brightness adjustment arrives right before distinction. After readjusting the keep an eye on’s distinction and brightness, change all preset and peripheral configurations.